Accufuser

Accufuser is a single-use elastomeric pump that works using the elasticity principle with a balloon reservoir made of medical-grade silicone inside a protective casing and a flow restrictor made of high-quality boron glass. Accufuser makes possible the highest possible mobility for the patients during their infusion and is a secure alternative to electronic pump systems.

Its advantages are:

  • Easy handling for patients, doctors, nursing staff, and pharmacists.
  • Small and discreet for patients
  • No irritating alarms
  • Works without batteries or electricity
  • Safety due to closed single-use system, kink-resistant tubing, and high-quality flow restrictor
  • Large selection of infusion rates and filling volumes for optimal adaptation to therapeutic needs

 

Article list 100 ml

Accufuser continuous 100 ml nominal filling volume. Recommended maximum filling volume 110 ml, recommended minimum filling volume not below 60 ml.

CodeFlow rateInfusion time in daysInfusion time in hoursPZNAid number
C0130M 13 ml/h   7.5 h 5950143 03 99 04 0 900
C0050M 5.0 ml/h 1 day 22 h 5950114 03 99 04 0 043
C0040M 4.0 ml/h 1 day 25 h 5950083 03 99 04 0 900
C0020M 2.0 ml/h 2 days 50 h 5950077 03 99 04 0 042
C0010M 1.0 ml/h 3-4 days 100 h 5950060 03 99 04 0 041
C0005M 0.5 ml/h 5-9 days 200 h 5950048 03 99 04 0 040

The infusion time given a flow rate (ml/h) is calculated using the filling volume. Infusion time (h) is equal to filling volume (ml) divided by flow rate (ml/h). E.g. a pump with 4 ml/h flow rate has to be filled to 96 ml to obtain a flow time of one day. if a reduced flow time is required, a flow rate of 5 ml/h and a pump filled with 110ml is required.

 

Article list 300 ml

Accufuser continuous 300 ml nominal filling volume. Recommended maximum filling volume 330 ml, recommended minimum filling volume not below 180 ml.

CodeFlow rateInfusion time in daysInfusion time in hoursPZNAid number
C0100L 10 ml/h 1 day 30 h 7797119 03 99 04 0 049
C0080L 8 ml/h 1½ days 37.5 h 7770617 03 99 04 0 048
C0050L 5.0 ml/h 2 - 2½ days 60 h 7770600 03 99 04 0 047
C0040L 4.0 ml/h 3 days 75 h   03 99 04 0 900
C0020L 2.0 ml/h 4-6 days 150 h 7703934 03 99 04 0 046
C0015L 1.5 ml/h 7-9 days 200 h 7704419 03 99 04 0 045
C0010L 1.0 ml/h 10 Days 300 h 5950195 03 99 04 0 900

The infusion time given a flow rate (ml/h) is calculated using the filling volume. Infusion time (h) is equal to filling volume (ml) divided by flow rate (ml/h). E.g. a pump with 2 ml/h flow rate has to be filled to 240 ml to obtain a flow time of five day.

Further models upon request

Accessories

Promecon carrier bags and Promecon carrier nets can be ordered using their names.

CONTACT PROMECON GMBH